Which column formwork system to use...
 
The following table has been created in order to assist you in your decision to select a system (or combination thereof) that is suitable to your column formwork needs. Each of these systems is carefully engineered to cater to your distinct requirements. 
 
 
                      Column System
Flex 50
TriTec
TriTec Light
Layout
Consistent
þ
 
 
Very variable
 
þ
þ
Wall height
Consistent
þ
þ
þ
Very variable
 
þ
 
Fresh concrete pressure
60 to 90 kN/m2
90 to 100 kN/m2
60 kN/m2
Ties
 
optimized
fixed
fixed
Fair-face concrete finish
þ
only with add. veneers
only with add. veneers
Choice of form lining
Type
þ
3 choices
3 choices
Size
þ
 
 
End-to-end joint
þ
 
 
Built-in
 
þ
þ
Number of re-uses
variable
up to 80x
up to 80x
 
 
 
Utilization
Low over short construction period
 
þ
þ
High over short construction period
 
þ
þ
Low over long construction period
þ
 
 
High over long construction period
þ
 
 
System service life/ number of re-use
New
150x
300x to 350x
200x to 250x
After re-fit
100x
200x
150x
 
Material costs
High
 
þ
 
Moderate
 
 
þ
Low
þ
 
 
Hire option (standard parts)
 
þ
 
Labour intensive
þ
 
 
Built-in safety
þ
þ
þ
Built-in stop ends
 
þ
þ
Crane independence
 
 
þ
Compatibility with German standards
þ
þ
þ
Re-use of panels and accessories between the systems
Struts only
þ
þ
 
þ Suitable / Proposed
Column Formwork | Adjustable Column Formwork